Title: Bond Degradation Due to The Desalination Process
Authors: 張建智
Contributors: 國立臺灣海洋大學:河海工程學系
Keywords: Desalination
Bond strength
Electrolyte
Chemical titration
Date: 2003-06
Issue Date: 2019-01-03T02:59:51Z
Publisher: Construction and Building Materials
Abstract: Abstract: In this paper, bond degradation due to the desalination process of chloride-contaminated reinforced concrete is investigated. Four different constant voltages were applied to study the effect of the current on the desalination. Two constant current densities were applied for comparison. Two different electrolytes, NaOH and Ca(OH)2, were used to examine the effect of electrolyte on the bond characteristics. Pullout specimens were cast and tested, using a single rebar pullout test. Three bond parameters of the bond strength, the critical debonding shear load per unit embedded rebar length and the shear stiffness per unit embedded rebar length were obtained to evaluate the bond quality after desalination. It is found that the bond characteristics decrease dramatically as the duration and/or the voltage of desalination increase. Using Ca(OH)2 solution as the electrolyte, less bond loss is observed than using NaOH solution. A micro-hardness experiment shows that softening of concrete near the rebar becomes more apparent as the desalination duration and/or desalination voltage increase. A chemical titration experiment indicates that the accumulation of potassium and sodium ions increases as the desalination duration and/or desalination voltage increase. A pH value measurement shows that the desalination current increases the pH value of concrete near the rebar. More than two-thirds of chloride ions migrate out of the rebar–concrete interface in two weeks of desalination with desalination voltage greater than 10 V. Bond strength decreases approximately 40–60%.
Relation: 17(4) pp.281-287
URI: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/51883
Appears in Collections:[河海工程學系] 期刊論文

Files in This Item:

File Description SizeFormat
index.html0KbHTML16View/Open


All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback