Title: The portable fluorescence detection system matched with PDMS microfluidic biochip for DNA hybridization detection
Authors: Yuh MingHsu
Chung ChengChang
Contributors: 國立臺灣海洋大學電機工程學系
Keywords: PDMS
Microfluidic biochip
Fluorescence
DNA hybridization
Embedded system
Date: 2015-10
Issue Date: 2018-12-14T01:39:07Z
Publisher: International Journal for Light and Electron Optics(Optik)
Abstract: Abstract: The self-made fluorescence detection system was integrated to detect the biological signal of DNA sample. And the portable fluorescence detection system with four channels microfluidic biochip was finished for DNA hybridization.
In the biochip preparation, the PDMS cast-forming process was used to fabricate microfluidic biochip with width 150 μm and height 200 μm. In the fluorescence detection system, four sets of independent 532 nm green lasers were adopted to illuminate the four detection areas of the microfluidic biochip for fluorescence sample excitation, then the voltage of excitation fluorescence signal was obtained. Then the PSOC embedded system was utilized synchronously to display the four voltage values on LCD, in the meantime, the voltage value was transferred to the computer for recording.

From the experimental result of DNA hybridization, it can be seen that portable fluorescence detection system can be utilized to measure four fluorescence signals of DNA samples at the same time. Moreover, due to the hybridization specificity of fluorescence probe ET996-Hex, the DNA hybridization of Edwardsiella tarda BCRC 16711 and Edwardsiella tarda BCRC 16702 can be judged successfully for fluorescence probe ET996-Hex. The portable fluorescence detection system had the capability to distinguish disease source.
Relation: 216(20) pp.2600-2605
URI: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/51648
Appears in Collections:[電機工程學系] 期刊論文

Files in This Item:

File Description SizeFormat
index.html0KbHTML17View/Open


All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback