Title: Corrosion resistance and biocompatibility of Ni-free Zr-based bulk metallic glass for biomedical applications
Authors: H.H. Huang
Y.S. Sun
C.P. Wu
C.F. Liu
P.K. Liaw
amd W. Kai
Contributors: 國立臺灣海洋大學:光電與材料科技學系
Keywords: Biocompatibility
Corrosion
Biomedical applications
Date: 2012-11
Issue Date: 2018-08-14T02:07:53Z
Publisher: Intermetallics
Abstract: Abstract: Aim:Currently, the potential applications of Ni-free bulk metallic glasses (BMGs) in biomedical fields that have been reported in the literature are still limited. In this study, the corrosion resistance and biocompatibility of Ni-free, Zr-based Zr50Cu43Al7 BMGs in biological environments were investigated.
Methods:The corrosion resistance was evaluated using potentiodynamic polarization curve measurements in simulated biological environments. The cytotoxicity was evaluated according to specification 10993-5 from the International Organization for Standardization (ISO). The protein (albumin) adsorption was evaluated using the bicinchoninic acid (BCA) assay. The adhesion and in situ migration of human bone marrow mesenchymal stem cells (hMSCs) were also evaluated.
Results:The main component on the outermost surface of Zr50Cu43Al7 BMG was ZrO2, with trace amounts of Cu and Al oxides. The corrosion rates of Zr50Cu43Al7 in artificial saliva and in simulated body fluid were comparable with those of biomedical Ti metal in the same environments; however, pitting corrosion was observed on Zr50Cu43Al7 in both environments. The cytotoxicity analysis results showed that Zr50Cu43Al7 was nontoxic. Compared with Ti metal, Zr50Cu43Al7 had a higher level of protein adsorption and better cell adhesion and cell migration.
Conclusion:Zr50Cu43Al7 BMG has the potential to be used in biomedical applications because of its corrosion resistance and cellular responses. However, further improvements to the pitting corrosion resistance of Zr50Cu43Al7 in biological environments should be made before proceeding to in vivo animal studies.
Relation: 30 pp.139-143
URI: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/48139
Appears in Collections:[光電科學研究所] 期刊論文

Files in This Item:

File Description SizeFormat
index.html0KbHTML20View/Open


All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback