Title: Void Fraction Measurements During Saturated Pool Boiling of Water on Partially Wetted Vertical Surfaces
Authors: S. P. Liaw;V. K. Dhir
Contributors: 國立臺灣海洋大學:機械與機電工程學系
Date: 1989-01
Issue Date: 2017-04-11T06:32:24Z
Publisher: J. Heat Transfer
Abstract: Abstract:Void fraction profiles adjacent to a vertical wall 6.3 cm wide and 10.3 cm high were measured during nucleate boiling. The experiments were conducted in saturated water at 1 atm pressure. In the experiments, the wettability of the surface was varied by controlling the degree of oxidation of the surface. Static contact angle was used as an indicator of the surface wettability. The void fraction was measured with a gamma densitometer. The experimental results show that the maximum void fraction occurs about 1–1.5 mm away from the heater surface. The wall void fraction, the maximum void fraction, and the thickness of the void layer increase with wall heat flux. It is found that for a given heat flux, the wall void fraction increases as the surface becomes less wettable, whereas the maximum heat flux decreases with increase in contact angle.
Relation: 111(3) pp.731-738
URI: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/41902
Appears in Collections:[機械與機電工程學系] 期刊論文

Files in This Item:

There are no files associated with this item.



All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback