English  |  正體中文  |  简体中文  |  Items with full text/Total items : 26988/38789
Visitors : 2348616      Online Users : 35
RC Version 4.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Adv. Search
LoginUploadHelpAboutAdminister

Please use this identifier to cite or link to this item: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/38476

Title: Nitrite ion-induced fluorescence quenching of luminescent BSA-Au25 nanoclusters: mechanism and application
Authors: Binesh Unnikrishnan;Shih-Chun Wei;Wei-Jane Chiu;Jinshun Cang;Pang-Hung Hsu;Chih-Ching Huang
Contributors: 國立臺灣海洋大學:生命科學暨生物科技學系
Date: 2014
Issue Date: 2016-09-07T06:04:29Z
Publisher: Analyst
Abstract: Abstract: Fluorescence quenching is an interesting phenomenon which is highly useful in developing fluorescence based sensors. A thorough understanding of the fluorescence quenching mechanism is essential to develop efficient sensors. In this work, we investigate different aspects governing the nitrite ion-induced fluorescence quenching of luminescent bovine serum albumin stabilized gold nanoclusters (BSA-Au NCs) and their application for detection of nitrite in urine. The probable events leading to photoluminescence (PL) quenching by nitrite ions were discussed on the basis of the results obtained from ultraviolet-visible (UV-Vis) absorption spectroscopy, X-ray photoelectron spectroscopy (XPS), fluorescence measurements, circular dichroism (CD) spectroscopy, zeta potential and dynamic light scattering (DLS) studies. These studies suggested that PL quenching mainly occurred through the oxidation of Au(0) atoms to Au(I) atoms in the core of BSA-Au NCs mediated by nitrite ions. The interference caused by certain species such as Hg2+, Cu2+, CN−, S2−, glutathione, cysteine, etc. during the nitrite determination by fluorescence quenching was eliminated by using masking agents and optimising the conditions. Based on these findings we proposed a BSA-Au NC-modified membrane based sensor which would be more convenient for the real life applications such as nitrite detection in urine samples. The BSA-Au NC-modified nitrocellulose membrane (NCM) enabled the detection of nitrite at a level as low as 100 nM in aqueous solutions. This Au NC-based paper probe was validated to exhibit good performance for nitrite analysis in environmental water and urine samples, which makes it useful in practical applications.
Relation: 139
URI: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/38476
Appears in Collections:[生命科學系] 期刊論文

Files in This Item:

File Description SizeFormat
index.html0KbHTML76View/Open


All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback