Title: A Knee Arthrometer for Measuring Varus, Valgus, and Rotation
Authors: Chen-Chou Lin
Contributors: 國立臺灣海洋大學:機械與機電工程學系
Date: 2013
Issue Date: 2016-03-02T07:32:56Z
Publisher: Proceedings of 6th International Conference on Biomedical Engineering and Informatics
Abstract: Due to the characteristics of cruciate ligaments, knee ligament tears are not suitable to heal by remedy. Anterior cruciate ligament (ACL) reconstruction is one of the most common and reliable surgeries to handle knee ligament injuries. To date, most knee ligament reconstructions can be done by using endoscopic surgery. Although single bundle ACL reconstructions could improve the recovery of knee function, yet it was still not enough for the stability of the knee joint. In some cases instability might even develop to be osteoarthritis. Via some vitro tests, such as varus, valgus and rotation tests, the test results showed that the ligament after single bundle ACL reconstruction was not able to bear the rotational, and varus/valgus torque at the knee joint. That means using conventional arthrometer such as KT-1000 could lead to misdiagnosis in the above mentioned situation. We developed a new instrument to measure the extent of tibia's varus, valgus and rotation relative to the femur. Via the test data, the instrument could quantify the knee laxity and help surgeon to diagnose the injured knee more accurately and verify whether an ACL reconstruction was successful. The main function of the instrument is to test knee ligament laxity by measuring the varus/valgus angulation, and internal/external rotation with high sensitivity and data reproducibility. We verified the instrument's performance via experiments. The results of the experiments demonstrated the usability of the arthrometer.
URI: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/37474
http://ntour.ntou.edu.tw:8080/ir/handle/987654321/37475
Appears in Collections:[機械與機電工程學系] 博碩士論文

Files in This Item:

There are no files associated with this item.



All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback