English  |  正體中文  |  简体中文  |  Items with full text/Total items : 26988/38789
Visitors : 2346761      Online Users : 34
RC Version 4.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Adv. Search
LoginUploadHelpAboutAdminister

Please use this identifier to cite or link to this item: http://ntour.ntou.edu.tw:8080/ir/handle/987654321/32234

Title: Monitoring the Variations of the Groundwater in the Unconfined Aquifer with the Time-Lapse Resistivity Imaging Method during the Stepwise Pumping Test
Authors: Chang P.;Chang L.;Chen W.;Chang S.;Chiang C.
Contributors: NTOU:Institute of Applied Geosciences
國立臺灣海洋大學:應用地球科學研究所
Date: 2011-12
Issue Date: 2012-06-15T07:43:34Z
Publisher: Eos Trans. AGU,Fall Meet
Abstract: abstract:In this study, we have conducted the electrical resistivity imaging monitoring during a well pumping test at the Pengtsuo site in Pingtung, Taiwan. Water level gauges were installed in the four wells, including P1, W1, O1 and O2, at the Pengtsuo site with different screen depths for the observation. The pumping test has design to be conducted in three stages. In the first stage the stepwise pumping were executed the in the P1 well for about 15 hours. Then the pumping was stopped for 8 hours for the recovery test in the second stage. The pumping in P1 was resumed and remained in a constant rate for another 48 hours for further analysis in the third stage. We conducted the resistivity monitoring in the first and second stage to examine if the resistivity imaging method is able to resolve the variation due to the pumping. The survey line is crossing the four wells in order to compare the resistivity measurements with the water level records. The preliminary results show that the electrical resistivity imaging is able to resolve the change of the water level at a range of tens of centimeters to over one meter. Vertical resistivity structures at the well position also reveal that the influences from the steel well casing. Therefore the resistivity difference image can be better to show the variation of the resistivity due to only the pumping test. We are currently working on the resistivity differences and the relative water level difference data in the hope to calculate the transmissivity and specific yield from the resistivity data.
Relation: 92(52), Suppl., Abstract H34E-1262
URI: http://ntour.ntou.edu.tw/handle/987654321/32234
Appears in Collections:[應用地球科學研究所] 演講及研討會

Files in This Item:

There are no files associated with this item.



All items in NTOUR are protected by copyright, with all rights reserved.

 


著作權政策宣告: 本網站之內容為國立臺灣海洋大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用,請合理使用本網站之內容,以尊重著作權人之權益。
網站維護: 海大圖資處 圖書系統組
DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback